性能
噪音水平 |
45 dB |
波形 |
Sine |
浪涌保护 |
Y |
发声警报器 |
Y |
UPS 拓扑 |
Line-Interactive |
浪涌保护功能 |
Digital Subscriber Line (DSL), Fax, Modem, Network, Telephone |
自动电压调节器(AVR) |
Y |
输出传送时间(最小值) |
10 ms |
输出传送时间(最大值) |
12 ms |
发声警报模式 |
Low battery alarm, Overload alarm |
能量控制
输入工作电压(最大值) |
300 V |
输入工作电压(最小值) |
156 V |
效率 |
98.9% |
电源输入频率 |
50/60 Hz |
能量波动功率 |
441 J |
输出功率(瓦特-安培) |
1500 VA |
波峰因数 |
3:1 |
输出频率调节 |
50/60 Hz |
输出功率 |
865 W |
端口 & 界面
USB端口 |
Y |
输出IEC跳 线数量 |
2 |
交流电(AC)插座数量 |
10 AC outlet(s) |
电池
电池容量 |
187 VAh |
热插拔电池 |
Y |
电池充电时间 |
8 h |
半载典型备用时间 |
12.4 min |
全载典型备用时间 |
3.7 min |
替换电池盒 |
APCRBC124 |
冷启动 |
Y |
自动电池测试 |
Y |
电池使用寿命(最大值) |
5 year(s) |
环境条件
非运行高度 |
0 - 15000 m |
工作高度 |
0 - 9000 m |
其他功能
额定输入电压 |
230 V |
名义输出电压 |
230 V |
Power Saving Back-UPS Pro 1500, 230V
Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Power-saving outlets
Automatically cuts power to idle equipment to conserve electricity.
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.
Extendable Run Time
Additional batteries can be added to provide power to the load for an extended period of time in the event of utility supply failure.
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment
Cold-start capable
Provides temporary battery power when the utility power is out.
Serial Connectivity
Use any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Dataline Surge Protection
Provides protection of connected equipment from power surges on the data lines.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.