APC Symmetra LX 16kVA Scalable to 16kVA N+1 Ext. Run Tower, 208/240V

APC Symmetra LX 16kVA Scalable to 16kVA N+1 Ext. Run Tower, 208/240V

EAN: 731304218951
MPN: SYAF16KXR9I
发送方式:
交货来源:
德国
更新价格... 📣 询问价格 Не поставляется
运输成本:
От

凡购买和价格 (Advertising *)

顶部
в наличии
* Alle Preise inkl. der jeweils geltenden gesetzlichen Mehrwertsteuer, ggfs. zzgl. Versandkosten. Alle Angaben ohne Gewähr. Preisänderungen sind in der Zwischenzeit möglich.

技术特点

顶部

端口 & 界面

串口数量 1

性能

噪音水平 62 dB
发声警报器 Y

电池

电池类型 SYBT5
电池充电时间 7.5 h
替换电池盒 9

其他功能

通讯选项卡 AP9619
输出连接器 2PH+N+G
通讯选项插槽 Smart-Slot
输出电压说明 120/208V, 120/240V

环境条件

非运行高度 0 - 4500 m
工作高度 0 - 3000 m

能量控制

输出功率(瓦特-安培) 16000 VA
输出功率 12800 W
12.8kW / 1600VA, 208V, 240V Input / 120V, 208V Output APC Symmetra, 12.8 kW / 16 kVA,Input 208V / Output 120V, 208V, Interface Port DB-9 RS-232, Smart-Slot, Extended runtime model

Includes: CD with software, Documentation CD, Installation guide, User Manual, Web/SNMP Management Card

SYA16K16PXR Features

Shippable with modules installed
Enables pre-installation UPS staging and testing and faster installation.

Removable input/output wiring tray
Allows quick and easy installation and maintenance of the UPS.

Availability:

Modular design
Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.

Configurable for N+1 internal redundancy
Provides high availabilty through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.

Redundant Intelligence Modules
Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.

Hot-swappable intelligence modules
Ensures clean, uninterrupted power to protected equipment during Intelligence Module replacement.

Hot-swappable power modules
Ensures clean, uninterrupted power to protected equipment during Power Module replacement.

Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced

Power Modules connected in parallel
Enhances availability by allowing immediate, seamless recovery from isolated module failures.

Battery modules connected in parallel
Delivers higher availability through redundant batteries.

Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS overload condition or fault.

Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.

Scalability:

Scalable power capacity
Reduces UPS over-sizing costs today by allowing quick upgrades later.

Scalable runtime
Allows additional run time to be quickly added as needed.

Plug-and-Play external batteries
Ensures clean, uninterrupted power to the loads when adding extra runtime to the UPS.

Field-replaceable power distribution panel
Ensures compatibility with equipment that has different plug types.

Programmable frequency
Ensures compatibility with different input frequencies.

Manageability:

Manageable external batteries
Reduces preventative maintenance service needs by monitoring the health and status of the external batteries and their expected runtime.

Network manageable
Provides remote management of the UPS over the network.

InfraStruXure Manager Compatible
Enables centralized management via the APC InfraStruXure Manager.

LCD display
Alpha-Numeric Display which displays system parameters and alarms.

Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.

SmartSlot
Customize UPS capabilities with management cards.

Serviceability:

Predictive failure notification
Provides early-warning fault analysis ensuring proactive component replacement.

Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.

User-replaceable intelligence modules
Enables simple upgrades and replacements of the Intelligence Modules.

User-replaceable power modules
Enables simple upgrades and replacements of the Power Modules.

User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)

Disconnected battery notification
Warns when a battery is not available to provide backup power.

Protection:

Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.

Frequency and voltage regulation
Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.

Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.

Generator compatible
Ensures clean, uninterrupted power to the loads in the event of an extended power outage

Cold-start capable
Provides temporary battery power when the utility power is out.

Resettable circuit breakers
Enables a quick recovery from overload events.

Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Фотографии

    密码恢复
    要恢复您的密码,请在下面您的电子邮件地址框与您已注册请输入:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    发生了错误。请检查您的电子邮件地址,然后再试一次。
    Ваш новый пароль:

    名称为空


    Выберите страну доставки

    您还没有写消息

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    已发送您的消息!

    親密

    1
    产品目录
    取消
    Бренды:
      Выберите бренды
        查看更多
          地區搜索
          全球
          Категории
            产品名称