APC Symmetra PX 100kW Double-conversion (Online) 100000VA Black uninterruptible power supply (UPS)

APC Symmetra PX 100kW Double-conversion (Online) 100000VA Black uninterruptible power supply (UPS)

MPN: SY100K100F-NB
发送方式:
交货来源:
德国
更新价格... 📣 询问价格 Не поставляется
运输成本:
От

凡购买和价格 (Advertising *)

顶部
в наличии
* Alle Preise inkl. der jeweils geltenden gesetzlichen Mehrwertsteuer, ggfs. zzgl. Versandkosten. Alle Angaben ohne Gewähr. Preisänderungen sind in der Zwischenzeit möglich.

技术特点

顶部

性能

波形 Sine
噪音水平 67 dB
发声警报器 Y
UPS 拓扑 Double-conversion (Online)
发声警报模式 Alarm when on battery, Low battery alarm

能量控制

输入工作电压(最大值) 239 V
输入工作电压(最小值) 177 V
最大电流 332 A
THD输出电压 2%
电源输入频率 40 - 70 Hz
THD输入电流 5%
输出功率(瓦特-安培) 100000 VA
输出工作电压(最小值) 120 V
输出工作电压(最大值) 208 V
输入功率因数 0.98
输出频率调节 57 - 63 Hz
输出功率 100000 W

认证标准

能源之星认证 Y

管理功能

网上管理 Y

技术细节

输出频率 60 Hz

电池

自动电池测试 Y

端口 & 界面

SmartSlot 智能插槽 Y

环境条件

工作高度 0 - 999.9 m
100kW, 100kVA, 208V, 60Hz, 600x1070x2011mm, 571kg, Black Symmetra PX 100kW Scalable to 100kW, 208V with Startup, No Battery

- Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
- Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
- Advanced electrical features
Excellent power conditioning, very low harmonic distortion through IGBT rectifier, input power factor correction, and high power efficiency
- Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Total Cost of Ownership

- Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
- Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
- 5x8 Start-up service included
Required for full coverage of factory warranty
- Fully-rated power kVA equals kW
Reduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.

Agility

- Programmable frequency
Ensures compatibility with different input frequencies.
- Scalable power capacity
Reduces UPS over-sizing costs today by allowing quick power upgrades, within the same footprint, later.
- SmartSlot
Customize UPS capabilities with management cards.

Sustainability

- ENERGY STAR for UPS
Establishes that the efficiency of the UPS is in the top 25% of the market as verified by third party testing
- EU CoC for UPS
Ensures that UPSs sold in the EU are highly efficient

Manageability

- LED status indicators
Quickly understand unit and power status with visual indicators.
- Audible alarms
Provides notification of changing utility power and UPS power conditions
- Integrates with StruxureWare Data Center Expert
An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network

Marketing Features

- Battery modules connected in parallel
Delivers higher availability through redundant batteries.
- Configurable for N+1 internal redundancy
Provides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.
- Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
- Scalable power capacity
Reduces UPS over-sizing costs today by allowing quick power upgrades, within the same footprint, later.
- Power Modules connected in parallel
Enhances availability by allowing immediate, seamless recovery from isolated module failures.
- User-replaceable power modules
Enables simple upgrades and replacements of the Power Modules.
- Modular design
Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
- Network manageable
Provides remote power management of the UPS over the network.
- User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
- Fully-rated power kVA equals kW
Reduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.

Availability

- Configurable for N+1 internal redundancy
Provides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.
- Redundant Intelligence Modules
Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.
- Power Modules connected in parallel
Enhances availability by allowing immediate, seamless recovery from isolated module failures.
- Swappable power modules
Allows quick addition of power capacity or replacement of existing power modules. Installed modules are automatically recognized by the system.
- Modular design
Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
- Network manageable
Provides remote power management of the UPS over the network.
- Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS power overload or fault.
Фотографии

    密码恢复
    要恢复您的密码,请在下面您的电子邮件地址框与您已注册请输入:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    发生了错误。请检查您的电子邮件地址,然后再试一次。
    Ваш новый пароль:

    名称为空


    Выберите страну доставки

    您还没有写消息

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    已发送您的消息!

    親密

    1
    产品目录
    取消
    Бренды:
      Выберите бренды
        查看更多
          地區搜索
          全球
          Категории
            产品名称