Wago 753-467 fieldbus module Wago 753-467. Signal direction: Input, Dimensions (WxDxH): 12 x 100 x 69.8 mm, Relative humidity: 0 - 95
Wago 750-559/025-000 fieldbus module 4-ch analog out, 0 ... 10 VDC, Ext. Temperature
The analog output module generates signals of a standard magnitude 0–10V.\n\nThe output signal is ele
Wago 753-653 fieldbus module Wago 753-653. Signal direction: Input/output, Serial interface type: RS-485, Dimensions (WxDxH): 12 x 100 x 69.8 m
Wago 750-670 fieldbus module Wago 750-670. Channels quantity: 2 channels, Isolation: 0.5 kV. Signal direction: Output, Input current range: 0 - 2.8 mA, Serial interface type: RS-
Wago 753-501 fieldbus module 2-channel digital output; 24 VDC; 0.5 A
This digital output module transmits control signals from the automation device to the connected actuators.\n
Wago 750-514 fieldbus module 2-ch digital out, 125 VAC, 0.5 A, Potential-free, Relay, 2 make contacts
This digital output module transmits control signals from the automation dev
Wago 750-506 fieldbus module 2-ch digital out, 24 VDC, 0.5 A, Diagnostics
This digital output module transmits control signals from the automation device to the connected actuato
Wago 753-502 fieldbus module Wago 753-502. Signal direction: Output, Output current range: 0 - 2 A, Dimensions (WxDxH): 12 x 100 x 69.8 m
Wago 753-531 fieldbus module Wago 753-531. Signal direction: Output, Dimensions (WxDxH): 12 x 100 x 69.8 mm, Relative humidity: 0 - 95
Wago 753-604 fieldbus module Wago 753-604. Signal direction: Output, Dimensions (WxDxH): 12 x 100 x 69.8 mm, Relative humidity: 0 - 95
Wago 750-454 fieldbus module 2-ch analog in, 2- to 4-conductor connection, Differential input
The analog input module processes signals of a standard magnitude 4–20mA.\n\nThe inp
Wago 750-469/000-008 fieldbus module 2-ch analog in, Thermocouple E, Diagnostics
This input module allows the direct connection of two thermocouples. Internal electrical isolation allows
Wago 753-530 fieldbus module Wago 753-530. Signal direction: Output, Output current range: 0 - 0.5 A, Dimensions (WxDxH): 12 x 100 x 69 m
Wago 750-511 fieldbus module 2 pulse width outputs, 24 VDC, 0.1 A, 250 kHz
This output module modulates a 16-bit information in the pulse width. The field side is electrically is
Wago 750-461 fieldbus module 2-ch analog in, f/ Pt100/RTD esistance sensors
The input module directly connects to Pt resistance sensors.\n\nThe connection of 2- or 3-conductor se
Wago 750-461/000-005 fieldbus module 2-ch analog in, f/ Ni1000/RTD resistance sensors
The input module directly connects to Ni resistance sensors.\n\nThe connection of 2- or 3-conductor
Wago 750-469 fieldbus module 2-ch analog in, Thermocouple K, Diagnostics
This input module allows the direct connection of two thermocouples. Internal electrical isolation allows
Wago 753-550 fieldbus module Wago 753-550. Signal direction: Output, Dimensions (WxDxH): 12 x 100 x 69.8 mm, Relative humidity: 0 - 95
Wago 750-437 fieldbus module 8-ch digital in, 24 VDC, 0.2 ms, Low-side switching
The digital input module provides 8 channels in a width of just 12mm (0.47in.). It receives contr
Wago 750-511/000-002 fieldbus module 2 pulse width out, 24 VDC, 0.1 A, 100 Hz
Wago 750-653/025-018 fieldbus module RS-485 Serial Interface, 9600 baud, None, 8/1 bits, 5 bytes, Ext. Temperature
The interface integrated in the I/O module allows the connection of any
Wago 753-509 fieldbus module Wago 753-509. Signal direction: Output, Dimensions (WxDxH): 12 x 100 x 69.8 mm, Relative humidity: 0 - 95
Wago 750-456 fieldbus module 2-ch analog in, ±10 VDC
The analog input module processes signals of a standard magnitude ±10V.\n\nThe input signal is electrically isolated and is t
Wago 750-655 fieldbus module Wago 750-655. Channels quantity: 1 channels, Isolation: 0.5 kV. Signal direction: Input/output, Dimensions (WxDxH): 12 x 100 x 67.8 mm, Power consump
Wago 750-671 fieldbus module Wago 750-671. Signal direction: Input/output, Dimensions (WxDxH): 12 x 100 x 67.8 mm, Relative humidity: 0 - 95
Wago 750-501 fieldbus module 2-ch digital out, 24 VDC, 0.5 A
This digital output module transmits control signals from the automation device to the connected actuators.\n\nAll ou
Wago 750-554/000-200 fieldbus module 2-ch analog out, 2- to 4-conductor connection, S5 PLC
The analog output module generates signals of a standard magnitude 4–20mA.\n\nThe output signal
Wago 750-430 fieldbus module 8-ch digital in, 24 VDC, 3 ms
The digital input module provides 8 channels in a width of just 12mm (0.47in.). It receives control signals from digita
Wago 750-517 fieldbus module 2-ch digital out, AC 250 V, 1 A, Potential-free, Relay, 2 changeover contacts
This digital output module transmits control signals from the automatio
Wago 750-650/000-002 fieldbus module RS-232 C Serial Interface, 9600 baud, Even, 7/2 bits
The interface integrated in the I/O module allows the connection of any device which is equipped
Wago 750-469/000-002 fieldbus module 2-ch analog in, Thermocouple T, Diagnostics
This input module allows the direct connection of two thermocouples. Internal electrical isolation allows
Wago 750-493 fieldbus module 3-Phase Power Measurement, 480 VAC, 1 A
The 750-493 3-Phase Power Measurement Module measures the electrical data in a three-phase supply network.\n\
Wago 750-454/025-000 fieldbus module 2-ch analog in, 2- to 4-conductor connection, Differential in, Ext. Temperature
The analog input module processes signals of a standard magnitude 4–2
Wago 750-650/000-010 fieldbus module RS-232 C Serial Interface, 19200 baud, None, 8/1 bits
The interface integrated in the I/O module allows the connection of any device which is equippe
Wago 753-483 fieldbus module Wago 753-483. Signal direction: Input, Dimensions (WxDxH): 12 x 100 x 69.8 mm, Relative humidity: 0 - 95
Wago 750-454/000-200 fieldbus module 2-ch analog in, 2- to 4-conductor connection, Differential input, S5 PLC
The analog input module processes signals of a standard magnitude 4–20mA.\n\
Wago 753-433 fieldbus module Wago 753-433. Signal direction: Input, Dimensions (WxDxH): 12 x 100 x 69.8 m
Wago 753-472 fieldbus module Wago 753-472. Signal direction: Input, Dimensions (WxDxH): 12 x 100 x 69.8 mm, Relative humidity: 0 - 95
Wago 750-483 fieldbus module 2-ch analog in, 0 ... 30 VDC, Differential in
The 2-channel analog input module processes differential signals of a standard magnitude 0–30VDC.\n\nTh
Wago 750-650/000-012 fieldbus module RS-232 C Serial Interface, 2400 baud, None, 8/1 bits
The interface integrated in the I/O module allows the connection of any device which is equipped
Wago 753-465 fieldbus module 2-ch analog in, 0 … 20 mA, Single-ended
The analog input module powers the transducers, receives transmitted analog signals, and with electrical isol
Wago 753-466 fieldbus module 2-ch analog in, 2- to 4-conductor connection, Single-ended
The analog input module powers the transducers, receives transmitted analog signals, and w
Wago 750-469/000-003 fieldbus module 2-ch analog in, Thermocouple ±120 mV, Diagnostics
This input module allows the direct connection of two thermocouples. Internal electrical isolation
Wago 750-653 fieldbus module Wago 750-653. Signal direction: Input/output, Serial interface type: RS-485, Dimensions (WxDxH): 12 x 100 x 69.8 m
Wago 753-403 fieldbus module Wago 753-403. Signal direction: Input, Dimensions (WxDxH): 12 x 100 x 69.8 m
Wago 753-425 fieldbus module Wago 753-425. Signal direction: Input, Dimensions (WxDxH): 12 x 100 x 69.8 m
Wago 750-459 fieldbus module 4-ch analog in, 0 ... 10 VDC, Single-ended
The analog input module processes signals of a standard magnitude 0–10V.\n\nThe input signal is electrical
Wago 750-472 fieldbus module 2-ch analog in, 0 … 20 mA, Single-ended, 16 bits
The analog input module powers the transducers, receives transmitted analog signals, and with electr
Wago 750-436 fieldbus module 8-ch digital in, 24 VDC, 3 ms, Low-side switching
The digital input module provides 8 channels in a width of just 12mm (0.47in.). It receives control
Wago 753-474 fieldbus module Wago 753-474. Signal direction: Input, Input current range: 4 - 20 mA, Dimensions (WxDxH): 12 x 100 x 69.8 m