CyberPower PDU15MV16FNET 16AC outlet(s) 0U Black power distribution unit (PDU)

CyberPower PDU15MV16FNET 16AC outlet(s) 0U Black power distribution unit (PDU)

MPN: PDU15MV16FNET
发送方式:
交货来源:
德国
更新价格... 📣 询问价格 Не поставляется
运输成本:
От

凡购买和价格 (Advertising *)

顶部
в наличии
* Alle Preise inkl. der jeweils geltenden gesetzlichen Mehrwertsteuer, ggfs. zzgl. Versandkosten. Alle Angaben ohne Gewähr. Preisänderungen sind in der Zwischenzeit möglich.

技术特点

顶部

端口 & 界面

串口数量 1
电源插头 NEMA 5–15P

管理功能

管理平台 SNMP

环境条件

非运行高度 0 - 15000 m
工作高度 0 - 4500 m

设计

PDU类型 Monitored

能量控制

最大电流 14 A
接受频率 50/60 Hz
名义输出电压 120 V
电源保护功能 Overload
额定输入电压 120 V

另外

以太网路(RJ-45)连接接口数量 1
Monitored, NEMA 5-15P In, 16 x NEMA 5-15R Out, RJ45, DB9/RS232, 0U The CyberPower (PDU15MV16FNET) 16-outlet 0U rack mount monitored power distribution unit (PDU) provides 120V 15A output. It distributes power to 16 NEMA 5-15R receptacles from a single NEMA 5-15P plug, with unfiltered electrical pass-through. Power status can be monitored over the network, using CyberPower Management Console and the RJ45 Ethernet port for network connection, or locally using the LCD.

The front LCD panel provides local monitoring of the PDU. Load management is accomplished by using the display to measure the electrical current used by connected equipment in amps. The LCD can also display input voltages to assist in diagnosing potential issues with input power. Power being consumed in watts can also be displayed, as well as, the IP address of the network interface for ease of installation.

The CyberPower Management Console offers real-time remote monitoring of PDU vitals of the outlets on networked clients. Event Logging via a web browser/network connection to review history on power conditions, such as input voltages, load levels, and outlet status. Automatic event notifications via Email or SNMP Trap are sent to designated user when specified power events occur.

Designed for datacenters and other electrically demanding applications, this unit has a rugged, industrial-grade metal housing and a 10-foot AC power cord. A RJ-45 port enables the connection of the optional ENVIROSENSOR environmental sensor for monitoring the heat and humidity in an IT center. It can be mounted either horizontally or vertically, includes a cord retention tray and is UL60950_1 and FCC Class A certified. A three-year warranty ensures that this PDU is free of defects in design, assembly, material or workmanship.
Фотографии

    密码恢复
    要恢复您的密码,请在下面您的电子邮件地址框与您已注册请输入:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    发生了错误。请检查您的电子邮件地址,然后再试一次。
    Ваш новый пароль:

    名称为空


    Выберите страну доставки

    您还没有写消息

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    已发送您的消息!

    親密

    1
    产品目录
    取消
    Бренды:
      Выберите бренды
        查看更多
          地區搜索
          全球
          Категории
            产品名称