IBM ServeRAID M5210 SAS/SATA Controller PCI Express x8 3.0 12Gbit/s RAID controller

IBM ServeRAID M5210 SAS/SATA Controller PCI Express x8 3.0 12Gbit/s RAID controller

EAN: 883436446327
MPN: 46C9110
发送方式:
交货来源:
德国
更新价格... 📣 询问价格 Не поставляется
运输成本:
От

凡购买和价格 (Advertising *)

顶部
в наличии
* Alle Preise inkl. der jeweils geltenden gesetzlichen Mehrwertsteuer, ggfs. zzgl. Versandkosten. Alle Angaben ohne Gewähr. Preisänderungen sind in der Zwischenzeit möglich.

技术特点

顶部

性能

最大容量 2 TB
S.M.A.R.T. 支持 Y
内存时钟速度 1866 MHz
内存类型 DDR3
数据传输率 12 Gbit/s
RAID 配置 1, 10
认证 UL, cUL, IEC60950, EMC, FCC, TUV, CE, VCCI, BSMI, C-tick, KC

端口 & 界面

PCI卡电路板 Half-height (low-profile)
内部Mini-SAS端口 2
支持存储驱动器界面 SAS, Serial ATA
内部SATA端口数量 8
主机接口 PCI Express x8
PCI Express插槽版本 3.0

重量和尺寸

深度 168 mm
重量 99 g
宽度 69 mm
高度 15 mm
包装重量 320 g
包装尺寸(宽度 × 深度 × 高度) 143 x 238 x 51 mm

系统要求

可支持的Mac操作系统 Y
可支持的Windows操作系统 Y

环境条件

运行湿度范围(H-H) 8 - 93%

另外

运行温度范围(T - T) 5 - 40 °C
ServeRAID M5210 SAS/SATA Controller for IBM System x Features
The ServeRAID M5210 and M5210e SAS/SATA controllers have the following standard features:

- Auto-resume on array rebuild or array reconstruction after the loss of system power

Auto-resume uses non-volatile RAM (NVRAM) to save the rebuild progress during a host reboot or
power failure to automatically resume from the last checkpoint. Auto-resume ensures that data
integrity is maintained throughout the process. The card supports a number of features that can be
implemented without rebooting the server. Applications, such as email and web server, benefit from
avoiding downtime during the transition.

- Online Capacity Expansion

Online Capacity Expansion (OCE) allows the capacity of a virtual disk to be expanded by adding new
physical disks or making use of unused space on existing disks, without requiring a reboot.

- Online RAID Level Migration

Online RAID Level Migration, which is also known as logical drive migration, can migrate a virtual
disk from any RAID level to any other RAID level without requiring a reboot. System availability and
application functionality remain unaffected.

- Fast initialization for quick array setup

Fast initialization quickly writes zeros to the first and last sectors of the virtual drive. This feature
allows you to immediately start writing data to the virtual drive while the initialization is running in the background.

- Consistency check for background data integrity

Consistency check verifies that all stripes in a virtual disk with a redundant RAID level are consistent. The consistency check mirrors data when an inconsistent stripe is detected for RAID 1 and re-creates the parity from the peer disks for RAID 5 or RAID 6. Consistency checks can be scheduled to take place periodically.

Extensive online configuration options and advanced monitoring and event notification

Management tools provide convenience for the configuration of logical volumes and alerting when
errors have occurred or are about to occur.

Patrol read for media scanning and repairing

Patrol read is a background sentry service that pro-actively discovers and corrects media defects
(bad sectors) that arise normally as a disk drive ages. The service issues a series of verify
commands, and if a bad block is discovered, the card's firmware uses RAID algorithms to re-create
the missing data and remap the sector to a good sector. The task is interruptible based on controller activity and host operations. The firmware also provides an interface where the patrol read task can be initiated, set up for continuous operation, and terminated from a management application. Patrol read can be activated by a manual command or automatically.

- Global and dedicated hot spare with revertible hot spare support

A hot spare rebuilds data from all virtual disks within the disk group in which it is configured.
ServeRAID can define a physical disk as a hot spare to replace a failed drive. Hot spares can be
configured as either global or dedicated. A global hot spare allows any physical drive to be
designated as a hot spare. A dedicated hot spare allows the user to assign a hot spare drive to a
particular array of the same drive type.

Drive roaming

Drive roaming occurs when the physical disks are changed to different ports on the same controller.
When the drives are placed on different channels, the controller detects the RAID configuration from
the configuration data on the drives.
Фотографии

    密码恢复
    要恢复您的密码,请在下面您的电子邮件地址框与您已注册请输入:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    发生了错误。请检查您的电子邮件地址,然后再试一次。
    Ваш новый пароль:

    名称为空


    Выберите страну доставки

    您还没有写消息

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    已发送您的消息!

    親密

    1
    产品目录
    取消
    Бренды:
      Выберите бренды
        查看更多
          地區搜索
          全球
          Категории
            产品名称