A08U-G1410 SATA single controller RAID subsystem with SCSI-320, 8 hard drives
A08U-G1410
SATA single controller RAID subsystem with SCSI-320 host I/F providing full- featured RAID functionality
SATA-to-PATA dongle kit to accommodate parallel ATA (PATA) drives
Support 8 hard drives
Auto switch cache policy and auto shutdown
Support for up to 1GB cache memory
Up to 64TB capacity per Logical Drive (LD) (OS dependent)
Intelligent drive handling
RAID:
Multiple arrays configurable with dedicated or global hot spares
RAID levels supported: RAID 0, 1 (0+1), 3, 5, 10, 30, 50, NRAID and JBOD
Online expansion by:
Adding new drives
Copying and replacing drives with drives of larger capacity
Automatic background rebuild
Configurable stripe size and write policy per array
Intelligent drive handling:
In degraded mode: skips irreparable blocks to continue rebuild
In normal operation: data-block verification and repair
Host Interface:
2 x SCSI-320 through dual-VHDCI 68-pin SCSI ports; SCSI-160 backward compatible
Concurrent I/O commands
Tagged command queuing up to 256
Variable stripe size per logical drive
Optimization setting for random or sequential I/Os
Drive Interface:
Eight (8) 1.5Gbps SATA, hot-swappable drive trays that accommodate 1-inch pitch, 3.5-inch SATA disk drives
16 hot-swappable drive trays
Automatic bad-sector reassignment
Dedicated bandwidth to each connected drive
System Components:
Redundant, hot-swappable components, designed for no single point of failure
One (1) EonStor® 2U enclosure
One (1) RAID controller module
One (1) 128MB SDRAM DIMM module (pre-installed on the controller module)
Two (2), hot-swappable, redundant, 350W power supply units
Two (2), hot-swappable, redundant, single-fan cooling modules
Eight (8), hot-swappable, drive trays
Two (2) front handles
Management:
Front LCD control panel for setup and configuration
10/100 BaseT Ethernet for out-of-band management
RS-232C for local access to firmware-embedded utility
Firmware-embedded Java-based RAIDWatch® GUI manager
VT-100 terminal emulation via RS-232C
Telnet access via onboard Ethernet port
Cross-platform, remote administration with SSL
Out-of-band access via Ethernet (GUI-onboard)
Centralized management to monitor and administer multiple RAID units on one screen
SNMP agent support:
SNMP trap event notification with plain-text event message (no MIB file required)
SNMP V2.0 MIB file support with get-and-set commands
Indicators:
Onboard alarm is triggered when one of the following modules fails:
RAID controller module
Cooling module
Power supply unit
Hard drive