Riello DLD800 ТМ 8000VA Grey uninterruptible power supply (UPS)

Riello DLD800 ТМ 8000VA Grey uninterruptible power supply (UPS)

MPN: UTM38K0A5A
发送方式:
交货来源:
德国
更新价格... 📣 询问价格 Не поставляется
运输成本:
От

凡购买和价格 (Advertising *)

顶部
в наличии
* Alle Preise inkl. der jeweils geltenden gesetzlichen Mehrwertsteuer, ggfs. zzgl. Versandkosten. Alle Angaben ohne Gewähr. Preisänderungen sind in der Zwischenzeit möglich.

技术特点

顶部

能量控制

功率因数 0.95
电源输入频率 50/60 Hz
输出功率(瓦特-安培) 8000 VA
输出功率 6400 W

性能

噪音水平 45 dB
相数 3

端口 & 界面

串口数量 1

其他功能

接口 USB, RS232
Mac兼容性 Y

电池

热插拔电池 Y
电池充电时间 4 h
半载典型备用时间 8 min
Dialog Dual, DLD800 ТМ, 8000VA, 6400W Dialog Dual\nThe DIALOG DUAL range is available in 3.3-4-5-6-8-10kVA single-phase models and 6.5-8-10kVA three-phase/single-phase models, with on-line double conversion (VFI) technology.\nThe DIALOG DUAL range may be placed directly on the floor or mounted in 19” rackmount cabinets such as the Multi Shelter range.\nIn terms of technology, features (selectable On-line, Economy and Smart Active operating modes), and diagnostics such as the digital display, RS232 and USB interfaces, network adaptor card option and PowerShield³ software include. DIALOG DUAL is easily the best solution for protecting "mission critical" applications requiring the highest levels of reliability.\nDIALOG DUAL is ideally suited for a whole range of applications from IT to security.\n\nFLEXIBILITY OF INSTALLATION AND USE\n- the UPS can be installed as a floor standing tower or 19" rackmount UPS.\nThe front panel digital display can be pulled out (using the keys provided) and rotated to suite the installation format\n- low noise level (<40dBA) thanks to the digitally PWM controlled ventilation system which is load and temperature dependent, and the use of an inverter with a high switching frequency (>20kHZ, above the audible range). DIALOG Dual is suitable for installation in any populated environment.\nUSER SELECTABLE CUSTOMISATION OPTIONS\n- Operating modes:\n- On-line (VFI): the inverter powers the load continuously\n- Economy: the UPS mimics a Line Interactive (VI) UPS supporting the load from its battery supply when the mains fails or fluctuates wildly\n- Smart Active: the UPS selects automatically whether to operate in On-line (VFI) or Line Interactive (VI) mode depending on the stability of the mains supply\n- Emergency: the UPS only supports the load with its batteries when the mains fails - suitable for emergency lighting\n- Frequency conversion 50 or 60Hz\n- Output voltage selection: 220-230-240Vac single-phase or 380-400-415Vac three-phase\n- Auto restart the mains returns from the front panel or PowerShield³ software\n- Automatic output delay when the UPS powers up\n- Automatic power down when no load is present\n- End of battery discharge pre-alarm.\n\nQUALITY OF POWER SUPPLY\n- Filtered, stable and reliable voltage - On Line double conversion (VFI) technology in accordance with EN50091-3, a with EMI filters\n- Guaranteed output quality even with typical distorting IT loads with crest factors of 3:1\n- Low impact on the mains supply as the UPS has an input power factory near to 1, with a sinusoidal input current.\nHIGHLY RELIABLE\n- Completely digitally controlled\n- Uninterrupted automatic by-pass\n- The by-pass can be activated manually\n- Use of IMS (Insulated Metallic Substrates) modules.\nADVANCED DIAGNOSTICS\n- Status, measurements, and alarms available on the standard backlit display\n- UPS can be updated digitally (flash upgradeable).\nOPTIMAL BATTERY MANAGEMENT\n- Reliable battery performance (automatic and manual battery tests)\n- Prolonged battery life due to the unique Low Ripple Current Discharge (LRCD)\n- ‘Hot-swap’ user replaceable batteries\n- Extendible back-up time using additional Battery Extension Packs or Trays\n- Increased ride through (without batteries) on mains breaks up to 40ms and for fluctuations ranging from 84 to 276Vac.\nENHANCED ELECTRICAL PERFORMANCE\n- Input protected by resettable thermally activated switch\n- Back-feed protection: to avoid energy being fed back into the mains should a fault occur\n- Increased short circuit current on the by-pass\n- Increased overload capacity: 150% on inverter even without a mains supply present\n- Performance guaranteed in temperatures up to 40°C short term\n- Manual switch to by-pass.\nMICROSOFT CERTIFICATION\nThe UPS and communication software have been certified by Microsoft laboratories.
Фотографии

    密码恢复
    要恢复您的密码,请在下面您的电子邮件地址框与您已注册请输入:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    发生了错误。请检查您的电子邮件地址,然后再试一次。
    Ваш новый пароль:

    名称为空


    Выберите страну доставки

    您还没有写消息

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    已发送您的消息!

    親密

    1
    产品目录
    取消
    Бренды:
      Выберите бренды
        查看更多
          地區搜索
          全球
          Категории
            产品名称