Riello Sentinel Power 6000 6000VA Grey uninterruptible power supply (UPS)

Riello Sentinel Power 6000 6000VA Grey uninterruptible power supply (UPS)

EAN: 8023251003202
MPN: SPW 6000
发送方式:
交货来源:
德国
更新价格... 📣 询问价格 Не поставляется
运输成本:
От

凡购买和价格 (Advertising *)

顶部
в наличии
* Alle Preise inkl. der jeweils geltenden gesetzlichen Mehrwertsteuer, ggfs. zzgl. Versandkosten. Alle Angaben ohne Gewähr. Preisänderungen sind in der Zwischenzeit möglich.

技术特点

顶部

性能

噪音水平 45 dB
电源保护功能 Over current, Over voltage, Short circuit, Under voltage

能量控制

输入工作电压(最大值) 240 V
输入工作电压(最小值) 220 V
电源输入频率 50/60 Hz
输出功率(瓦特-安培) 6000 VA
波峰因数 3:1
输出工作电压(最小值) 220 V
输出工作电压(最大值) 240 V
输出功率 4800 W

端口 & 界面

电源插头 Terminal

电池

电池充电时间 8 h

另外

RS-232接口 1
6000 VA, 4800 W, 45 dB, 91 kg, Grey SENTINEL POWER is the ideal solution for powering vital mission critical, sensitive loads such as electro-medical security applications in order to guarantee maximum reliability and availability.

The series includes 5kVA-6kVA single/single phase and 6.5kVA-8kVA-10kVA single/single phase and three/single phase models and uses double conversion on-line technology (VFI). The load is powered constantly by the inverter which supplies filtered, stabilised and regulated sinewave voltage.
Moreover, the input and output filters increase the immunity of the load against mains power disturbances and lightning strikes.

SENTINEL POWER is without doubt one of the best UPS systems on the market today thanks to the technology used, the features (selectable Economy Mode and Smart Mode) and the diagnostics offered (custom LCD display, RS232 and USB interfaces complete with Powershield³ software, EPO contact and slots for optional interface boards).


HIGH UPS RELIABILITY
- Full microprocessor control.
- No break static and maintenance bypass.
- Features guaranteed up to 40°C (the components are designed to operate at high temperatures and thus are subject to less stress at ordinary temperatures).

SELECTABLE OPERATING MODES
The operating mode can be programmed using the software or selected manually on the digital front panel display.
- On line Mode (VFI).
- Economy Mode: increases efficiency (up to 98%), and uses Line Interactive (VI) technology to power low priority loads from the mains supply.
- Smart Mode: the UPS automatically decides which operating mode to use (VI or VFI) depending on the quality of the mains supply.
- Emergency Mode: the UPS can be set to operate only when mains power fails (emergency only mode).
- Frequency converter Mode (50 or 60 Hz).

HIGH QUALITY OUTPUT VOLTAGE
- Even with distorting loads (IT loads with crest factor of up to 3:1).
- High short circuit current on bypass.
- High overload capacity: 150% on inverter, even when mains power fails.
- Filtered, stabilised and reliable voltage (double conversion on-line technology, VFI compliant with EN62040-3 specifications, with filters to suppress atmospheric interference).
- Rephasing of the load: UPS input power factor close to 1 with sinusoidal current absorption.

SIMPLIFIED INSTALLATION
- The UPS can be connected to both single phase and three phase mains supplies.
- Output terminal board + 2 IEC plugs to power local equipment (computers, modems, etc.).
- Easy to move thanks to built-in wheels.

HIGH BATTERY RELIABILITY
- Automatic and manual battery tests.
- Low Ripple Current Discharge system “LRCD” to prolong battery life.
- Unlimited extendable runtime thanks to dedicated modular design Battery Boxes.
- Increased ride-through for mains failures up to 40ms (high hold up time) and for fluctuations in the input current ranging from 84V to 276V).

LOW IMPACT ON MAINS POWER
- Sinusoidal input current on single phase/single phase series.

OTHER FEATURES
- Filtered, stabilised and reliable current (double conversion on-line technology, VFI compliant with EN62040-3 specifications, with filters to suppress atmospheric interference).
- Advanced diagnostics: status, measurements and alarms available on the custom LCD display
- Very low noise level (<40dBA): for installation in any environment thanks to the PWM digitally controlled ventilation that is load dependent, and the use of an inverter with high switching frequency
- (>20kHz, value above the audible range)
- Autorestart when mains power returns, can be programmed using software or the digital front panel display
- Emergency mode: the UPS can be programmed to work only when mains power fails (suitable for emergency lighting)
- Standard back feed protection: to avoid current being fed back into the mains system.
- Digital updating of the UPS (flash upgradable)
Фотографии

    密码恢复
    要恢复您的密码,请在下面您的电子邮件地址框与您已注册请输入:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    发生了错误。请检查您的电子邮件地址,然后再试一次。
    Ваш новый пароль:

    名称为空


    Выберите страну доставки

    您还没有写消息

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    已发送您的消息!

    親密

    1
    产品目录
    取消
    Бренды:
      Выберите бренды
        查看更多
          地區搜索
          全球
          Категории
            产品名称