Tripp Lite 2–2.4kW Single-Phase ATS/Metered PDU, 200–240V Outlets (10 C13), 2 C14 Inlets, 3.6 m Cords, 1U Rack-Mount

Tripp Lite 2–2.4kW Single-Phase ATS/Metered PDU, 200–240V Outlets (10 C13), 2 C14 Inlets, 3.6 m Cords, 1U Rack-Mount

MPN: PDUMH15HVAT
发送方式:
交货来源:
德国
更新价格... 📣 询问价格 Не поставляется
运输成本:
От

凡购买和价格 (Advertising *)

顶部
в наличии
* Alle Preise inkl. der jeweils geltenden gesetzlichen Mehrwertsteuer, ggfs. zzgl. Versandkosten. Alle Angaben ohne Gewähr. Preisänderungen sind in der Zwischenzeit möglich.

技术特点

顶部

能量控制

最大功率 2400 W
最大电流 10 A
接受频率 50/60 Hz
额定输入电压 200-240 V

端口 & 界面

交流电(AC)插座数量 10 AC outlet(s)
电源插头 IEC 320

设计

PDU类型 Switched, Metered

环境条件

工作高度 0 - 3000 m
2–2.4kW Single-Phase ATS/Metered PDU, 200–240V Outlets (10 C13), 2 C14 Inlets, 3.6 m Cords, 1U Rack-Mount The PDUMH15HVAT 2–2.4kW Single-Phase 200–240V ATS/Metered PDU enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and features 10 C13 outlets. Dual 3.6-meter input cords with IEC-320 C14 plugs connect to separate primary and secondary single-phase power sources in a nominal voltage range from 200–240V. Plug lock inserts prevent cords from accidental disconnection. The PDUMH15HVAT constantly evaluates the power quality of both input sources. Dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 2–5 milliseconds should the primary source fail or become unstable to ensure your connected equipment operates without interruption. Built-in slot supports the optional SNMPWEBCARD and WEBCARDLX (sold separately), which turn the PDUMH15HVAT into a switched PDU by allowing remote access to the PDU for power monitoring, configuration, outlet control and notifications via web browser, SSH, telnet or SNMP. Digital ammeter monitors total output current. LEDs display outlet on/off status and input power status on primary and secondary inputs.

Primary and Secondary Inputs for Power Redundancy
● Enables redundant power for network devices with non-redundant power supply configurations
● Dual 3.6 m input cords with IEC-320 C14 plugs connect to separate primary and secondary single-phase power sources
● 10 C13 outlets

Automatic Transfer Switching
● Dynamic solid-state (TRIAC) automatic transfer switching
● Switches to secondary power source if primary source fails or becomes unstable
● 2–5 ms transfer time ensures uninterrupted operation of connected equipment
● Built-in processor monitors both sources and prevents switching if secondary source is unavailable or of lower quality than primary source

Digital Load Meter
● Easy-to-read ammeter displays total current used by connected equipment

LED Indicators
● Individual LEDs display outlet on/off status and input power status on primary and secondary inputs

Advanced Network Monitoring Options
● Built-in card slot accommodates SNMPWEBCARD and WEBCARDLX accessories (sold separately)
● Optional cards create a switched PDU by allowing remote access for power monitoring, configuration, outlet control and notification via web browser, SSH, telnet or SNMP

Mounts Horizontally in 1U of Rack Space
● Compatible with EIA-standard 19 in. racks
● Single-phase IEC-320 C14 input and 200–240V output
● 10 C13 outlets
● Automatic transfer switching within 5 ms
● Mounts in 1U of space in EIA-standard 19 in. racks
● Digital load meter for real-time output current monitoring

Package Includes

● PDUMH15HVAT TAA-Compliant 2–2.4kW Single-Phase ATS/Metered PDU
● (10) C14 plug lock inserts
● (2) C13 to C14 power cords, 3.6 m (11.8 ft.)
● (2) Mounting brackets, horizontal
● (2) Mounting brackets, vertical
● (6) Screws
● Owner’s manual
Фотографии

    密码恢复
    要恢复您的密码,请在下面您的电子邮件地址框与您已注册请输入:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    发生了错误。请检查您的电子邮件地址,然后再试一次。
    Ваш новый пароль:

    名称为空


    Выберите страну доставки

    您还没有写消息

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    已发送您的消息!

    親密

    1
    产品目录
    取消
    Бренды:
      Выберите бренды
        查看更多
          地區搜索
          全球
          Категории
            产品名称