Tripp Lite 7.4kW Single-Phase 230V ATS/Monitored PDU, IEC309 32A Blue Outlet, 2 IEC309 32A Blue Inputs, 1U Rack-Mount

Tripp Lite 7.4kW Single-Phase 230V ATS/Monitored PDU, IEC309 32A Blue Outlet, 2 IEC309 32A Blue Inputs, 1U Rack-Mount

EAN: 37332187871
MPN: PDUMNH32HVAT
发送方式:
交货来源:
德国
更新价格... 📣 询问价格 Не поставляется
运输成本:
От

凡购买和价格 (Advertising *)

顶部
в наличии
* Alle Preise inkl. der jeweils geltenden gesetzlichen Mehrwertsteuer, ggfs. zzgl. Versandkosten. Alle Angaben ohne Gewähr. Preisänderungen sind in der Zwischenzeit möglich.

技术特点

顶部

能量控制

最大功率 7400 W
最大电流 32 A
接受频率 50/60 Hz
名义输出电压 230 V
额定输入电压 200-240 V

端口 & 界面

交流电(AC)插座数量 2 AC outlet(s)
电源插头 IEC309

设计

PDU类型 Monitored

环境条件

工作高度 0 - 3000 m
7.4kW Single-Phase 230V ATS/Monitored PDU, IEC309 32A Blue Outlet, 2 IEC309 32A Blue Inputs, 1U Rack-Mount The PDUMNH32HVAT 7.4kW Single-Phase 230V ATS/Monitored PDU provides remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations. Ideal for data centers and server rooms, it mounts in 1U of space in EIA-standard 19-inch racks and has an IEC 309 32A Blue outlet for connecting a single device or an additional 230V PDU with IEC 309 32A Blue plug, such as Tripp Lite’s PDUMV32HV. Dual 3.05 m (10-ft.) input cords with IEC 309 32A Blue plugs connect to separate primary and secondary single-phase power sources, including out-of-phase sources. The PDU constantly evaluates the power quality of both input sources. To ensure connected equipment remains powered, dynamic solid-state (TRIAC) automatic transfer switching allows the PDU to switch to the secondary source within 1–5 milliseconds if the primary source fails or becomes unstable. Built-in Ethernet network interface allows remote access to the PDU for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP. Provides real-time load/current data with billing-grade accuracy (+/- 1 percent). Tiered access privileges allow both an administrator and a guest to log in. Automated alerts help prevent overloads, power loss and downtime. Digital display with LEDs indicates power availability, voltage, input status for both power sources, output load and power factor, as well as temperature and humidity conditions with the optional ENVIROSENSE module (sold separately).

Primary and Secondary Inputs for Power Redundancy
● Offers remote power monitoring and enables redundant power for network devices with non-redundant power supply configurations
● IEC 309 32A Blue (2P+E) inputs with 3 m (10 ft.) cords connect to separate primary and secondary single-phase power sources
● Fault-tolerant, hot-swappable UPS protection when used with single UPS
● Fully redundant UPS protection when each cord is connected to separate UPS

Built-In IEC 309 32A Blue Outlet
● Powers a single device or indirectly powers equipment through a 0U 230V PDU with IEC 309 32A Blue (2P+E) input (sold separately)

Automatic Transfer Switching
● Dynamic solid-state (TRIAC) automatic transfer switching
● Switches to secondary power source if primary source fails or becomes unstable
● 1–5 ms transfer time ensures uninterrupted operation of connected equipment
● Built-in processor monitors power sources and prevents switching if secondary source is unavailable or of lower quality than primary source

Multifunction Digital Display with LEDs
● Reports input status for primary and secondary power sources, power availability, line voltage, frequency, amps, kilowatts and power factor

Advanced Network Monitoring
● Built-in Ethernet network interface allows full remote access for power monitoring, configuration, control and notifications via web browser, SSH, telnet or SNMP
● Real-time load/current data with billing-grade accuracy (+/- 1 percent)
● Tiered access privileges allow both an administrator and guest to log in
● Optional ENVIROSENSE module (sold separately) monitors temperature and humidity

Broad Communications Compatibility
● Supports HTTP, HTTPS, PowerAlert® Network Management System, SMTP, SNMPv1, SNMPv2, SNMPv3, Telnet, SSH, FTP, DHCP, BOOTP and NTP
● 10/100 Mbps auto-sensing for communication with 10/100 Base-T networks

Mounts Horizontally in 1U of Rack Space
● Compatible with EIA-standard 19 in. 4-post racks and rack enclosures
● Included PDU4PKIT rail kit adds rear rack-mounting support

● Two IEC 309 32A Blue (2P+E) inputs w/10 ft. (3 m) cords
● IEC 309 32A Blue (2P+E) outlet for connecting device or 0U PDU
● Automatic transfer switching within 1–5 ms
● Ethernet network interface for remote access
● Digital display with LEDs for real-time status monitoring

Package Includes

● PDUMNH32HVAT 7.4kW Single-Phase 230V ATS/Monitored PDU
● Rack-mounting brackets
● PDU4PKIT rear support rail kit
● Owner’s manual
Фотографии

    密码恢复
    要恢复您的密码,请在下面您的电子邮件地址框与您已注册请输入:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    发生了错误。请检查您的电子邮件地址,然后再试一次。
    Ваш новый пароль:

    名称为空


    Выберите страну доставки

    您还没有写消息

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    已发送您的消息!

    親密

    1
    产品目录
    取消
    Бренды:
      Выберите бренды
        查看更多
          地區搜索
          全球
          Категории
            产品名称