技术细节
频带 |
5 - 10000 kHz |
温度测量范围 |
-50 - 1000 °C |
直流电压范围 |
0.4 - 600 V |
交流电压范围 |
0.4 - 600 V |
背光 |
Y |
阻值范围 |
400 - 40000000 Ω |
基本准确度(直流电压) |
±(1.5%+3d), ±(0.8%+3d), ±(2.0%+3d) |
基本准确度(交流电压) |
±(1.8%+5d), ±(0.8%+20d), ±(2.5%+5d) |
基本准确度(交流电流) |
±(2.5%+10d), ±(2.5%+5d), ±(3.0%+4d) |
基本精度(电阻) |
±(1.0%+4d), ±(1.5%+2d), ±(2.5%+3d), ±(3.5%+5d) |
交流电流范围 |
40 - 1000 A |
连续性检查 |
Y |
数据保持 |
Y |
基本准确度(频率) |
±(1.2%+2d), ±(1.5%+5d), ±(1.5%+10d) |
基本精度(电容) |
±(5.0%+100d), ±(3.0%+5d), ±(3.5%+5d), ±(5.0%+5d) |
容量范围 |
40 - 100000 nF |
DCM267N, DCV & ACV max. 600V, ACA 1000A
DIGITAL CLAMP METER + DMM
- LCD display with automatic polarity indication
- data-hold function
- DCV (max. 600V) and ACV (max. 600V) measurements
- ACA (max. 1000A) current measurements
- max. Ø for conductor: 30mm
- resistance measurements: max. 40Mohm
- frequency measurements: max. 10MHz
- temperature measurements: -50°C to 1,000°C
- diode test, continuity test and backlight
- K-type thermocouple measuring range: from -20°C to 1000°C
- optional probes (not incl.): SONDE890, SONDE8264
- duty cycle measurements: 0.5 to 99% @ pulse width of 100µs to 100ms
- capacitance measurement: max. 100µF
- safety: indoor use only (overvoltage Cat. II 600V)
- DC voltage: 0.4/4/40/400/600V
- basic accuracy: ±(1.5% of rdg + 3 digits) / ±(0.8% of rdg + 3 digits) for 0.4V range / ±(2.0% of rdg + 3 digits) for 600V range
- input impedance: 7.8Mohm
- maximum input: 600V
- AC voltage: 0.4/4/40/400/600V
- basic accuracy: ±(1.8% of rdg + 5 digits) / ±(0.8% of rdg + 20 digits) for 0.4V range / ±(2.5% of rdg + 5 digits) for 600V range
- input impedance: 7.8Mohm
- frequency range: 50-60Hz
- maximum input: 600V
- AC current: 40/400/1000A (max. line voltage 240V)
- basic accuracy: ±(2.5% of rdg + 10 digits) for 40A range / ±(2.5% of rdg + 5 digits) for 400A range / ±(3.0% of rdg + 4 digits) for 1000A range
- overload protection: -
- resistance: 400/4K/40K/400K/4M/40M
- basic accuracy: ±(1.0% of rdg + 4 digits) for 400ohm range / ±(1.5% of rdg + 2 digits) for 4K~400K range / ±(2.5% of rdg + 3 digits) for 4M range / ±(3.5% of rdg + 5 digits) for 40M range
- overload protection: 15s max. 250V (all ranges)
- capacitance: 40n/400n/4µ/40µ/100µF
accuracy: ±(5.0% of rdg + 100 digits) for 40nF range / ±(3.0% of rdg + 5 digits) for 400nF range / ±(3.5% of rdg + 5 digits) for 4µ~40µF range / ±(5.0% of rdg + 5 digits) for 100µF range
- frequency: 5.000Hz/50.00Hz/500.0Hz/5.000KHz/50.00KHz/500.0KHz/5MHz/10.00MHz
- basic accuracy: ±(1.2% of rdg + 2 digits) / ±(1.5% of rdg + 5 digits) for 5Hz range / ±(1.5% of rdg + 10 digits) for 5MHz~10MHz range
- overload protection: 15s max. 250V (all ranges)
- temperature: -50°C-1,000°C
- basic accuracy: ±(3.0% of rdg + 5°C)
- overrange: yes "OL"
- continuity buzzer: yes
- diode test: yes
- low-battery indication: yes
- maximum display: 3999
- LCD display size: 22 x 35 mm
- ranging mode: auto/manual
- data hold: yes
- backlight: yes
- dimensions: 229 x 80 x 49mm
- weight: ±303g
- power supply: 1 x 9V battery (incl.)
- packaging: box
- accessories: manual / test leads / thermocouple / battery / carrying case
- auto power-off: yes