Performance
Noise level |
45 dB |
Audible alarm(s) |
Y |
Power
Input operation voltage (max) |
278 V |
Input operation voltage (min) |
160 V |
Efficiency |
95.8% |
Maximum current |
2 A |
Power supply input frequency |
45/65 Hz |
Surge energy rating |
273 J |
Output power capacity |
500 VA |
Output power |
300 W |
Operational conditions
Non-operating altitude |
0 - 9000 m |
Operating altitude |
0 - 3000 m |
Battery
Battery recharge time |
8 h |
Typical backup time at half load |
13 min |
Typical backup time at full load |
4 min |
Replacement battery cartridge |
APCRBC110 |
Cold start |
Y |
Number of batteries supported |
1 |
Ports & interfaces
AC outlets quantity |
4 AC outlet(s) |
Other features
Nominal input voltage |
230 V |
Nominal output voltage |
230 V |
Back-UPS 500VA, 300W, 230V, 4x Schuko CEE 7, 5.5kg
BC500-RS Features\n- Battery failure notification\nProvides early-warning fault analysis on batteries enabling timely preventive maintenance\n- LED Indicators\nProvide easy-to-read status of the unit and utility power conditions.\n- Resettable circuit breaker\nEasy recovery from overloads; no need to replace a fuse.\n- Replace Battery LED\nAn external Replace Battery LED informs the end-user that the battery needs to be replaced.\n- Cold-start capable\nProvides temporary battery power when the utility power is out.\n- Disconnected battery notification\nWarns when a battery is not available to provide backup power.\n- Audible alarms\nProvides notification of changing utility power and UPS power conditions\n- Intelligent battery management\nMaximizes battery performance, life, and reliability through intelligent, precision charging.\n\nProtection\n- Battery and surge protected outlets\nBack up and protect your hardware and data during power outages, surges and spikes.\n- Surge only outlets\nProtect secondary electronics from surges and spikes without reducing battery power used to run primary electronics during an outage.\n\nAvailability\n- Automatic self-test\nPeriodic battery self-test ensures early detection of a battery that needs to be replaced.\n- Battery failure notification\nProvides early-warning fault analysis on batteries enabling timely preventive maintenance\n- Intelligent battery management\nMaximizes battery performance, life, and reliability through intelligent, precision charging.\n\nServiceability\n- Resettable circuit breaker\nEasy recovery from overloads; no need to replace a fuse.\n\nManageability\n- Audible alarms\nProvides notification of changing utility power and UPS power conditions\n- LED status display\nQuickly understand unit and power status with visual indicators.\n\nSafety\n- Safety-agency approved\nEnsures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.