Performance
| Noise level |
45 dB |
| Waveform |
Sine |
| Surge protection |
Y |
| Audible alarm(s) |
Y |
| UPS topology |
Line-Interactive |
| Surge protection features |
Digital Subscriber Line (DSL), Fax, Modem, Network, Telephone |
| Automatic Voltage Regulation (AVR) |
Y |
| Hold time (min) |
10 ms |
| Hold time (max) |
12 ms |
| Audible alarm modes |
Low battery alarm, Overload alarm |
Power
| Input operation voltage (max) |
300 V |
| Input operation voltage (min) |
156 V |
| Efficiency |
98.9% |
| Power supply input frequency |
50/60 Hz |
| Surge energy rating |
441 J |
| Output power capacity |
1500 VA |
| Crest factor |
3:1 |
| Output frequency regulation |
50/60 Hz |
| Output power |
865 W |
Technical details
| Input connections |
IEC-320 C14 |
Packaging content
| Software CD |
Y |
| Warranty card |
Y |
Ports & interfaces
| USB port |
Y |
| Number of output IEC jumpers |
2 |
| AC outlets quantity |
10 AC outlet(s) |
Battery
| Battery capacity |
187 VAh |
| Hot-swap battery |
Y |
| Battery recharge time |
8 h |
| Typical backup time at half load |
12.4 min |
| Typical backup time at full load |
3.7 min |
| Replacement battery cartridge |
APCRBC124 |
| Cold start |
Y |
| Automatic battery test |
Y |
| Battery life (max) |
5 year(s) |
Operational conditions
| Non-operating altitude |
0 - 15000 m |
| Operating altitude |
0 - 9000 m |
Other features
| Nominal input voltage |
230 V |
| Nominal output voltage |
230 V |
Logistics data
| Quantity per master carton |
1 pc(s) |
Power Saving Back-UPS Pro 1500, 230V
Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Power-saving outlets
Automatically cuts power to idle equipment to conserve electricity.
Resettable circuit breaker
Easy recovery from overloads; no need to replace a fuse.
Extendable Run Time
Additional batteries can be added to provide power to the load for an extended period of time in the event of utility supply failure.
Battery-protected and surge-only outlets
Reserves power capacity and run time for connected equipment that require battery back-up while providing surge only protection for less critical equipment
Cold-start capable
Provides temporary battery power when the utility power is out.
Serial Connectivity
Use any Home Automation network to monitor and control the S20 through its RS-232 serial port. For information on how to communicate with the S20, see APC's Application Note #102. Crestron and AMX installers should visit their respective websites for information on how to integrate the S20 into those networks.
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Dataline Surge Protection
Provides protection of connected equipment from power surges on the data lines.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.