Ports & interfaces
Cabling technology |
10/100Base-T |
Serial interface |
Y |
USB port |
Y |
Serial interface type |
RS-232 |
AC outlets quantity |
8 AC outlet(s) |
SmartSlot |
Y |
Performance
Waveform |
Sine |
Noise level |
45 dB |
Surge protection |
Y |
Auto-restart |
Y |
Audible alarm(s) |
Y |
UPS topology |
Line-Interactive |
Audible alarm modes |
Alarm when on battery, Low battery alarm |
Power
Input operation voltage (max) |
144 V |
Input operation voltage (min) |
75 V |
Power supply input frequency |
50/60 Hz |
Surge energy rating |
459 J |
Output power capacity |
1440 VA |
Output operation voltage (min) |
120 V |
Output operation voltage (max) |
120 V |
Output power |
1000 W |
Packaging content
Software CD |
Y |
Resource CD |
Y |
Battery
Battery capacity |
408 VAh |
Hot-swap battery |
Y |
Battery recharge time |
3 h |
Replacement battery cartridge |
RBC7 |
Cold start |
Y |
Automatic battery test |
Y |
Technical details
Output frequency |
50/60 Hz |
Operational conditions
Operating altitude |
0 - 3000 m |
1000W, 1.44kVA, 120V, 50/60Hz, 408VAh, 459J, 171x439x219mm, 24.09kg
APC Smart-UPS 1500VA LCD 120V with AP9631 Installed
Reliable network power protection designed for deployment in retail and open access environments.
Includes : CD with software , Documentation CD , Smart UPS signalling RS-232 cable , USB cable , Web/SNMP Management Card
- 10/100 BaseT Connection
Connect the device to a network using a 10 or 100 BaseT connection
- Cold-start capable
Provides temporary battery power when the utility power is out.
- Command line interface
Offers simultaneous remote management access through Telnet and SSH
- Customizable Input Contacts
Monitor conditions from external devices.
- Customizable Output Relays
Control output from external devices via output relay(s).
- Device Encryption
Securely connect via HTTPS/SSL, SSH (up to 2048-bit encryption), SNMPv3
- Energy meter
Provides actual kilowatt hours of usage for energy conscious users.
- Green mode
Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
- High online efficiency
Reduces utlility costs, generates less heat.
- Humidity monitoring
Changes in humidity are reported via the user interface or e-mail.
- Intuitive LCD interface
Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
- Predictive replace battery date
Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
- Pure sine wave output on battery
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
- Single switched outlet group
Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
- SmartSlot
Customize UPS capabilities with management cards.
- Temperature monitoring
Changes in temperature are reported via the user interface or e-mail.
- Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Serviceability
- Easy to install
Innovative design allows for fast, easy installation by almost anybody.
- User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
- Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- Technical support
Our experienced technical support engineers are available to answer your questions, giving you peace of mind knowing the help you need is there when you need it.
Availability
- Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
- Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
- Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
- Pure sine wave output on battery
Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
- Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Manageability
- USB connectivity
Provides management of the UPS via a USB port (not available on all models).
- SmartSlot
Customize UPS capabilities with management cards.
- Serial connectivity
Provides management of the UPS via a serial port.
- LED Indicators
Provide easy-to-read status of the unit and utility power conditions.
- Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.