Performance
Waveform |
Sine |
Noise level |
67 dB |
Audible alarm(s) |
Y |
UPS topology |
Double-conversion (Online) |
Audible alarm modes |
Alarm when on battery, Low battery alarm |
Power
Input operation voltage (max) |
239 V |
Input operation voltage (min) |
177 V |
Maximum current |
332 A |
Output voltage THD |
2% |
Power supply input frequency |
40 - 70 Hz |
Input current THD |
5% |
Output power capacity |
100000 VA |
Output operation voltage (min) |
120 V |
Output operation voltage (max) |
208 V |
Input power factor |
0.98 |
Output frequency regulation |
57 - 63 Hz |
Output power |
100000 W |
Operational conditions
Operating altitude |
0 - 999.9 m |
100kW, 100kVA, 208V, 60Hz, 600x1070x2011mm, 571kg, Black
Symmetra PX 100kW Scalable to 100kW, 208V with Startup, No Battery
- Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
- Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
- Advanced electrical features
Excellent power conditioning, very low harmonic distortion through IGBT rectifier, input power factor correction, and high power efficiency
- Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Total Cost of Ownership
- Input power factor correction
Minimizes installation costs by enabling the use of smaller generators and cabling.
- Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
- 5x8 Start-up service included
Required for full coverage of factory warranty
- Fully-rated power kVA equals kW
Reduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.
Agility
- Programmable frequency
Ensures compatibility with different input frequencies.
- Scalable power capacity
Reduces UPS over-sizing costs today by allowing quick power upgrades, within the same footprint, later.
- SmartSlot
Customize UPS capabilities with management cards.
Sustainability
- ENERGY STAR for UPS
Establishes that the efficiency of the UPS is in the top 25% of the market as verified by third party testing
- EU CoC for UPS
Ensures that UPSs sold in the EU are highly efficient
Manageability
- LED status indicators
Quickly understand unit and power status with visual indicators.
- Audible alarms
Provides notification of changing utility power and UPS power conditions
- Integrates with StruxureWare Data Center Expert
An IT-ready, scalable access monitoring system that collects, organizes, and distributes critical alerts, surveillance video and key information, providing a unified view of complex physical infrastructure environments from anywhere on the network
Marketing Features
- Battery modules connected in parallel
Delivers higher availability through redundant batteries.
- Configurable for N+1 internal redundancy
Provides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.
- Generator compatible
Ensures clean, uninterrupted power to protected equipment when generator power is used.
- Scalable power capacity
Reduces UPS over-sizing costs today by allowing quick power upgrades, within the same footprint, later.
- Power Modules connected in parallel
Enhances availability by allowing immediate, seamless recovery from isolated module failures.
- User-replaceable power modules
Enables simple upgrades and replacements of the Power Modules.
- Modular design
Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
- Network manageable
Provides remote power management of the UPS over the network.
- User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
- Fully-rated power kVA equals kW
Reduces cost by eliminating the need for an oversized UPS for Power Factor Corrected (PFC) loads.
Availability
- Configurable for N+1 internal redundancy
Provides high availability through redundancy by allowing configuration with one more Power Module than is necessary to support the connected load.
- Redundant Intelligence Modules
Provides higher availability to the UPS connected loads by giving redundant communication paths to critical UPS functions.
- Power Modules connected in parallel
Enhances availability by allowing immediate, seamless recovery from isolated module failures.
- Swappable power modules
Allows quick addition of power capacity or replacement of existing power modules. Installed modules are automatically recognized by the system.
- Modular design
Provides fast serviceability and reduced maintenance requirements via self-diagnosing, field-replaceable modules.
- Network manageable
Provides remote power management of the UPS over the network.
- Automatic internal bypass
Supplies utility power to the connected loads in the event of a UPS power overload or fault.