Lantronix UDS1100 RS-232/422/485 serial server

Lantronix UDS1100 RS-232/422/485 serial server

MPN: UD1100001-01
🚚 Select the country of delivery:
Delivery from:
Germany
Updating price ... 📣 Send Price inquiry Не поставляется
Delivery cost & estimated delivery time:
От
days

Where to buy and prices (Advertising *)

On Top
в наличии
* Alle Preise inkl. der jeweils geltenden gesetzlichen Mehrwertsteuer, ggfs. zzgl. Versandkosten. Alle Angaben ohne Gewähr. Preisänderungen sind in der Zwischenzeit möglich.

Technical specifications

On Top

Processor

Processor frequency 48 MHz

Technical details

Serial ports quantity 1
Isolation 1.5 kV
Electrostatic Discharge (ESD) protection 15 kV
Serial interface type RS-232/422/485
Data transfer rate 0.9216 Mbit/s
Ethernet LAN data rates 10, 100 Mbit/s

Ports & interfaces

Cabling technology 10/100Base-T(X)

Management features

Management protocols SNMP, Telnet, HTTP

Memory

Flash memory 2 MB

Protocols

Supported network protocols ARP, UDP, TCP, ICMP, Telnet, TFTP, AutoIP, DHCP, HTTP, SNMP TCP, UDP, Telnet, TFTP

Power

Input voltage 120 V

Additionally

Internal RAM 0.256 MB
Ethernet LAN (RJ-45) ports quantity 1
1 x DB25F DCE, 1 x 10/100Base-T RJ-45, DSTNI-EX 48 MHz, 256 KB SRAM, 2 MB Flash, LED Features:

- Network virtually any device in minutes
- Access, monitor and control equipment over Ethernet
- Replace dedicated PCs and/or modem lines with fast and reliable Ethernet networking
- Configure quickly and easily via HTTP, DHCP, Telnet, serial or Lantronix DeviceInstaller™ utility
- Supports RS232, RS422 and RS485 communications
- Environmentally-friendly RoHS and WEEE compliant
- Small enough to place almost anywhere
- Features TruPort Com port control technology (also see UDS2100)
- Power over Ethernet (PoE) model available
- Meets the newest UL 864 9th Edition standards

Device networking is what powers M2M (machine to machine) communication. The UDS family of external device servers enables users to connect, manage and control just about any piece of equipment with a serial port from virtually anywhere over Ethernet or the Internet.

With the UDS1100, virtually any piece of equipment can be added to an Ethernet network in a matter of minutes! This single-port external device server is a quick, simple and inexpensive way to bring the advantages of remote management to equipment not currently connected to a network.

And with the UL 864 listing, fire and alarm panel equipment manufactures can easily add networking capabilities to their existing UL 864-listed products without the need to reapply to UL.

Extending Serial to Ethernet Communications Across the Globe

Our approach to network-enabling devices is transparent to your attached equipment and software so you won’t need to change the way you work. Using a method called serial tunneling, the UDS1100 encapsulates serial data into packets and transports it over Ethernet. Serial tunneling can be done in two ways:

- Using Lantronix supplied Com Port Redirector software, Windows device applications not designed for network communications are re-directed to communicate to devices connected to the UDS1100.
- Connecting two UDS1100 device servers configured to automatically talk to each other over the network creates virtual serial to Ethernet connections that can extend serial communications across a facility or around the world.

The built-in web server enables users to access and configure the UDS1100 from a standard web browser.

Web pages enabling the UDS1100 to be customized for unique applications can be built using Lantronix development tools. On-board Flash memory provides room for future system software upgrades and maintenance-free, non-volatile web page storage.

Easy to Set Up and Use

The UDS1100 can be set up locally through its serial port, or remotely using Telnet or a web browser. The included DeviceInstaller Windows-based configuration software simplifies setup and provides an easy way to:

- Assign IP & other network specific addresses
- Load custom web pages
- Enable web-based configuration of the device server
- Ping or query the attached device(s) over the network
- View specific device data files
- Upgrade firmware

Modem Replacement

In modem emulation mode, the UDS is used to replace dial-up modems. The unit accepts modem AT commands on the serial port. It then establishes a network connection to the end device, leveraging network connections and bandwidth to eliminate dedicated modems and phone lines. The PoE version enables you to also take advantage of network connectivity in areas without power outlets.
Total Com Port Control with TruPort Technology

Built into the included Com Port Redirector software, TruPort technology enables Windows-based applications to access and control serial ports on the UDS1100 as if they were actually local PC serial ports. The application can monitor and set hardware pins on the UDS1100 serial ports as well as access serial buffers for total Com port control. This allows existing applications to seamlessly transition from controlling local devices to true remote monitoring and control of devices around the world.
Фотографии

    Password recovery
    To recover your password, please enter in the box below your email address with which you have registered:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    An error has occurred. Please check your e-mail address and try again.
    Ваш новый пароль:

    Name is empty


    Выберите страну доставки

    You have not written a message

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    Your message has been sent!

    Close

    1
    Catalog
    Cancel Close
    Бренды:
      Выберите бренды
        Show more close
          Area search
          Worldwide
          Категории
            Product