Power
Power factor |
0.9 |
Input operation voltage (max) |
240 V |
Input operation voltage (min) |
220 V |
Power supply input frequency |
50/60 Hz |
Input current THD |
2% |
Output power capacity |
1000 VA |
Output operation voltage (min) |
220 V |
Output operation voltage (max) |
240 V |
Output power factor |
0.9 |
Output voltage regulation |
1% |
Output frequency regulation |
0.05 Hz |
Output power |
900 W |
Packaging content
Manual |
Y |
Warranty card |
Y |
Quick installation guide |
Y |
Battery
Battery technology |
Sealed Lead Acid (VRLA) |
Battery recharge time |
4 h |
Automatic battery test |
Y |
Battery replacement alarms |
LED |
Certificates
Safety |
EN 62040-1:2008+A1:2013 |
Certification |
CE |
Weight & dimensions
Depth |
356 mm |
Width |
144 mm |
Weight |
10200 g |
Height |
228 mm |
Ports & interfaces
USB 2.0 ports quantity |
1 |
USB port |
Y |
Technical details
Voltage |
220 - 240 V |
Output frequency |
50/60 Hz |
Performance
LED indicators |
Y |
Noise level |
49 dB |
UPS topology |
Double-conversion (Online) |
Power protection features |
Short circuit, Under current, Under voltage |
Number of input phases |
1 |
Number of output phases |
1 |
Off-mode charging |
Y |
Audible alarm modes |
Fault, Overload alarm |
Operational conditions
Operating relative humidity (H-H) |
0 - 95% |
Design
Form factor |
Tower |
Display |
LCD |
Additionally
Colour of product |
Black |
Packaging type |
Box |
Operating temperature range (T-T) |
0 - 40 °C |
1000VA, 900W, Tower, USB, 50/60 Hz, 220 - 240V, 9.2kg black
SALICRU’s SLC TWIN PRO2 series is a UPS range in a tower format equipped with on-line double-conversion technology and the latest features to make it an advanced protection system for sensitive and critical loads. High output power factor (PF=0.9) to ensure availability to all types of loads.
Full control through status information via LCD display and keypad. And extensive monitoring and communication options via the built-in USB HID interface, an intelligent slot for SNMP cards or relays and a wide range of software packages available – free monitoring version downloadable for Windows, Linux, Unix or Mac and packages available for multi servers or virtualised systems. For facilities that require more back-up time, there is a possibility of backup extensions using UPSs with extra charger and additional battery modules. Also notable is the possibility of Eco-mode operation to improve the efficiency of the device, EPO (emergency power off) functions, operation as a frequency converter and built-in battery test.
Power supply failures in IT systems can cause losses as a result of downtime and the time taken to restore the system to normal operation, and damage to network hardware. Many other disturbances (micro power outages, voltage fluctuations, frequency variations, harmonics, transients, etc.) can also cause IT environments to malfunction.
- On-line double-conversion technology.
- Output power factor PF=0.9.
- Control panel with LCD screen and keypad.
- Tower format.
- Backup extensions available for all power ratings.
- UPS models with extra charger for backup extensions.
- USB HID interface for all models as standard.
- Downloadable monitoring software for Windows, Linux, Unix and Mac.
- Intelligent slot for SNMP/relays.
- Eco-mode operation.
- Automatic frequency detector.
- Frequency conversion function. EPO – emergency power off.
- Schuko or IEC sockets available.
- Manual and/or automatic programmable battery test.
- Smart battery charger to shorten average recharging times.
- Battery recharging with device turned off.
- SLC Greenergy solution.