Other features
Input connections |
NEMA 5-15P |
Power
Input frequency |
60 Hz |
Peak power |
250 W |
AC outlets quantity |
2 AC outlet(s) |
Surge energy rating |
680 J |
Nominal input voltage |
120 V |
IS250 - 250 W - 680 Joules
Tripp Lite Isolator series isolation transformers offer complete line isolation, continuous noise filtering and enhanced common mode surge suppression. Internal low-impedance isolation transformer component with Faraday Shield offers 100% isolation from the input AC line. Secondary neutral to ground bonding eliminates common mode noise, providing an isolated ground reference for sensitive equipment and an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades. Removes EMI/RFI noise, utility switching transients, background spikes generated by other on-site loads and utility or lightning related surge conditions. Additional surge suppression components placed at both the line input and transformer output combined with full line isolation offers continuous line filtering of a full range of power line noise in all modes. Active transformer filtering with no wearable parts is uniquely able to reduce surges in the worst of power environments to harmless levels. Reduces 6000V IEEE587 Cat A&B ring wave and combination wave test surges to only 0.5V common mode. Model IS250 offers 250 watts capacity with 2 widely spaced output receptacles, a 6-ft power cord, circuit breaker overload protection and lighted power switch. Rugged all-metal unit housing ships ready for upright tower or wallmount placement in industrial, medical, office or network environment.
- Tripp Lite Isolator series isolation transformers offer complete transformer-.based line isolation, continuous noise filetering and enhnanced common mode surge suppression
- Supports combined loads up to 250 watts continuous/2.1A at 120V.
- Isolation transformer with Faraday Shield offers 100% isolation from the input AC line.
- Neutral to ground bonding at the secondary eliminates common mode noise and provides an isolated ground reference for sensitive equipment.
- Isolation transformer design serves as an inexpensive alternative to the installation of dedicated circuits and site electrical upgrades.
- Removes EMI/RFI noise, utility switching transients, background spikes and power problems generated by other on-site loads, utility grid-switching and lightning related surges.
- Line isolation with additional surge suppression components offer continuous line filtering of a full range of power line noise in all modes.
- Active filtering with no wearable parts reduces surges in the worst of power environments to harmless levels.
- Includes 2 widely-spaced NEMA5-15R output receptacles, 6 ft power cord, circuit breaker overload protection and lighted power switch.
- Rugged all-metal housing ships ready for upright tower or wallmount installation.