Here you can compare the prices for thermostats GIRA, get acquainted with photos and technical characteristics (for example Temperature control range, Battery type, Smart thermostat, Spindle movement, Adapting speed, Potential free contact) and buy a liked model thermostats in one of the reliable online stores.
KNX CO2 Sensor with humidity and room temperature controller
- Limit value monitoring for CO2 concentration and humidity - Dewpoint alert e.g. for cooling ceilings and winter gardens to prevent possible mould growth. - Two binary inputs for connecting zero-voltage contacts. - Logic gates for easy linking functions.
- Up to four different limits can be set for the CO2-sensor. - Adaptation to current sea level above NN. - Up to two limits can be set for the humidity sensor.
- 5 operating modes: Comfort, standby, night, frost or heat protection, and controller lock-out (e.g. dew-point mode). - Heating/cooling functions: Heating, cooling, heating and cooling, basic and additional heating, basic and additional cooling. - Preset control parameters for common radiators or cooling units. - Controller deactivatable (dewpoint operation) or controller or operation of the controller can be blocked. - Valve protection function (valve is opened cyclically every 24 hours). - Control types: continuous PI control, switching PI control (PWM), and switching 2-point control (on/off).
- Free assignment of the functions switching, dimming, blind and value transmitter to the inputs. - Blocker for blocking individual inputs. - Behaviour can be configured following bus voltage recovery. - Telegram rate limiting. - Switching function: two independent switching objects are available for each existing input and can be enabled individually, command for leading and trailing edge can be set independently (ON, OFF, CHANGE, no reaction). - Dimming function: single-surface and double-surface operation, time between dimming and switching, and dim-step size can be set, telegram repetition and stop telegram transmission possible. - Blind function: command can be set with rising edge (no function, UP, DOWN, SW), operating concept can be parameterised, time between short and long-term operation adjustable, slat adjustment time adjustable. - Value transmitter and light scene auxiliary unit function: edge (push button as NO contact, push button as NC contact, switch) and value with edge can be configured, value adjustment by pressing and holding a button for value transmitters possible, light scene auxiliary unit with/without memory function.
By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.