Power

Power factor 0.99
Maximum current 14 A
Output voltage THD 3%
Power supply input frequency 50/60 Hz
Input current THD 8%
Output power capacity 3000 VA
Output power 2700 W

Performance

Noise level 52 dB
Audible alarm(s) Y

Ports & interfaces

Serial ports quantity 1

Other features

Interface RS-232, USB
Mac compatibility Y
Output connections 6 x IEC320 C13\n1 x IEC320 C19
Overload protection Y
Output voltage note 208 - 240V +/-2%

Battery

Hot-swap battery Y
Battery recharge time 3 h
Protect D.3000 with Battery Pack, 2U, 3000VA, 72VDC, 2700W, 2s/150%, 6 x IEC320 C13, 1 x IEC 320C19, RS-232, USB, 52dB, 70.5kg, Aluminium Protect D.3000 with Battery Pack
The Protect D. achieves more than 30% higher power in comparison to conventional uninterruptible power systems, due to its new power factor rating of 0.9 lagging across its operating range. Through careful component selection our UPS can provide outstanding performance, superior reliability and longer autonomy times.The reliable AEG electronics enables universal operation across the whole apparent and effective power range without loss of power, allowing the inverter to handle even very complex loads.

Continuous improvements in the efficiency of our double conversion, ECO and ECO+ modes is really evident when power consumption lowers, lowering the need for cooling and decreases the overall operating expense.

Compact Design
UPS electronics and battery are combined in only 2U of rack space. With the flip-over front cover it is easy to change the hot-swappable battery or to add external battery packs.

Autonomy time can be extended by preconfigured battery packs. The number of connected battery packs will be detected automatically. All battery packs are hot-swappable and can be connected without disconnecting the UPS, simply open the cover to swap.

Communication options
Extraordinary communication options are provided by the several interfaces including programmable potential-free contacts, emergency power off switch, RS232, USB and an extension slot that can be used in parallel mode with RS232/USB. The extension slot is compatible with optional accessories such as relay cards or SNMP adapter.

Battery management
The improved battery charging technology provides quicker charging time with a gentle charging characteristic. The battery management system is able to differentiate between initialization during setup, the battery charging phase (temperature compensated) and the standby phase. This enables the system to extend battery lifetime as there is a decrease of pole corrosion. An uncoupled battery charger avoids battery heating and inverter reflection effects.

Innovative output control
All UPS outlets are equipped with an innovative lock mechanism that prevents the connected cables from accidental disconnection. The UPS outlets can be managed by the user, allowing applications to be prioritized in the event of a power failure. These programmable outlets allow for easy load management or load shedding, enabling the user full flexibility in power distribution and energy management.

Graphical display
The multi-language graphical display supports better readability. It displays several parameters of the input, UPS mode and the output. Three LEDs at the top of the display indicate the current operating mode. From the control panel the user is able to configure the UPS setting and activate an audible alarm. All events are logged by an internal logger to allow events analysis. From the settings menu the user can control the UPS outputs according to the battery capacity and the delay after a power failure for the UPS to initialize a shut down. It is also possible to schedule for a battery test either daily, weekly or monthly.
Фотографии

    Password recovery
    To recover your password, please enter in the box below your email address with which you have registered:
    The password reset code has been sent to your Email.
    Код уже был отправлен Вам ранее.
    Вы можете ввести его в поле выше, или получить новый код через сек.
    An error has occurred. Please check your e-mail address and try again.
    Ваш новый пароль:

    Name is empty


    Выберите страну доставки

    You have not written a message

    By clicking on the "Send" button, you agree that your data will be used to process your request. Further information and revocation instructions can be found in the data protection declaration.

    Your message has been sent!

    Close

    1
    Catalog
    Cancel Close
    Бренды:
      Выберите бренды
        Show more close
          Area search
          Worldwide
          Категории
            Product