Technical details
| Frequency range |
0 - 100 kHz |
| Overrange |
Y |
| AC voltage range |
0 - 1000 V |
| Resistance range |
0 - 50 Ω |
| Basic accuracy (DC voltage) |
±(0.15% + 2) |
| Basic accuracy (AC voltage) |
±(1.0% + 3) |
| Basic accuracy (AC current) |
±(1.5% + 3) |
| Basic accuracy (DC current) |
±(1.0% + 3) |
| Basic accuracy (resistance) |
±(0.9% + 1) |
| Basic accuracy (capacitance) |
±(1.2% + 2) |
| Resolution (DC voltage) |
0.1 mV |
| Resolution (AC voltage) |
0.1 mV |
| Resolution (frequency) |
0.01 Hz |
| AC current range |
0 - 10 A |
| Data hold |
Y |
| Diode test |
Y |
| Statistic function |
Maximum |
| Measuring category |
CAT III 300V |
| Basic accuracy (frequency) |
±(0.1% + 1) |
| DC current range |
0 - 10 A |
| Capacitance range |
0 - 10000 nF |
| Resistance resolution |
0.1 Ω |
| Resolution (AC current) |
0.01 µA |
| DC voltage range |
0 - 1000 V |
| Resolution (DC current) |
0.01 µA |
The Fluke 175 True RMS Digital Multimeter is the baseline for professional technicians around the world. With features you need to troubleshoot and repair in electrical and electronic systems, the Fluke 175 CAT IV 600V/CAT III 1000 V digital multimeter provides accurate, True RMS readings through years of reliable service.
- Manual and automatic ranging
- Display Hold and Auto Hold
- Frequency and capacitance measurements
- Resistance, continuity and diode measurements
- Min-max-average recording
- Closed case calibration through front panel
- Ergonomic case with integrated protective holster
All inputs are protected to IEN61010-1 CAT IV 600 V/CAT III 1000 V. UL, CSA, TÜV listed and VDE Pending