Technical details
| Temperature measurement range |
-200 - 1090 °C |
| DC voltage range |
0 - 1000 V |
| Frequency range |
0 - 200 kHz |
| AC voltage range |
0 - 1000 V |
| Resolution (AC current) |
0.1 µA |
| Resistance range |
0 - 50000 Ω |
| Resistance resolution |
0.1 Ω |
| Capacitance range |
0 - 9999 nF |
| Resolution (frequency) |
0.01 Hz |
| Basic accuracy (DC voltage) |
±(0.05% + 1) |
| Basic accuracy (AC voltage) |
±(0.7% + 2) True RMS |
| Basic accuracy (AC current) |
±(1.0% + 2) True RMS |
| Basic accuracy (DC current) |
±(0.2% + 2) |
| Basic accuracy (capacitance) |
±(1% + 2) |
| Basic accuracy (resistance) |
±(0.2% + 1) |
| Resolution (AC voltage) |
0.1 mV |
| Resolution (DC voltage) |
10 mV |
| AC current range |
0 - 20 A |
| DC current range |
0 - 20 A |
| Resolution (DC current) |
0.01 µA |
| Basic accuracy (frequency) |
±(0.005% + 1) |
| Diode test |
Y |
Operational conditions
| Operating altitude |
0 - 2000 m |
Industrial Electrician Combo Kit, 1000 V AC/DC, 20 A, 200 kHz, 10,000 µF
Combo kit with the Fluke 87V Industrial Multimeter, heavy duty test leads, alligator clips and test probes, hanging strap, case.
This combo kit is built around the Fluke 87V, the most widely used industrial digital multimeter in the world, and includes special accessories to make you even more productive on the job. This kit will save over 15% compared with the individual price of all the accessories. Plus you'll be working with the most trusted tools in the world.
Electrical safety
All inputs are protected to the 2nd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600 V and CAT III, 1000 V. They can withstand impulses in excess of 8.000 V and reduce risks related to surges and spikes.
Correctly measure pulse-width modulated motor drive signals
Until now, there hasn't been a multimeter able to accurately measure adjustable speed drives. But the Fluke 87V is designed specifically to handle these complex signals. Think of the potential productivity you'll gain by taking the guesswork out of drive system troubleshooting. Measurements are correct each and every time.
- Unique function for accurate measurements of noisy pulse-width modulated AC voltage. Measures correctly at the ASD and at the motor terminals
- Accurately measure the frequency (motor speed). Frequency measurement not affected by the ASDs carrier frequency
- Measure AC current with an optional current clamp accessory
- Compare reading from the 87V with the display on the ASD
- Special shielding blocks high frequency, high-energy noise generated by large drive systems