Wago 750-530/025-000 Digital output module fieldbus module 8-channel digital output; 24 VDC; 0.5 A; Ext. Temperature
Wago 753-428 Digital input module fieldbus module 4-channel digital input; 42 VAC/VDC; 20 ms
Wago 750-428 Digital input module fieldbus module Wago 750-428. Product type: Digital input module, Channels quantity: 4 channels, Housing material: Polyamid, Polycarbonat. Width: 12 mm, Depth: 100 m
Wago 753-655 fieldbus module <b>AS Interface Master </b>\nThe 75x-655 AS-I Master Module connects AS-Interface systems to a higher-level fieldbus.\nThe module acts as
Wago 753-459 Analog input module fieldbus module 4-channel analog input, 0 - 10 V DC, Single-ended
<b>4-channel analog input; 0 ... 10 VDC; Single-ended </b>\nThe analog input module pro
Wago 753-456 Analog input module fieldbus module 2-channel analog input, ±10 VDC
<b>2-channel analog input; ±10 VDC </b>\nThe analog input module processes signals of a standard magnitud
Wago 753-455 Analog input module fieldbus module 4-channel analog input, 2- to 4-conductor connection, Single-ended
<b>4-channel analog input; 2- to 4-conductor connection; Single-ended</b&
Wago 753-454 Analog input module fieldbus module 2-channel analog input, 2- to 4-conductor connection, Differential input
2-channel analog input; 2- to 4-conductor connection; Differential input \n\
Wago 750-651 fieldbus module <b>Serial TTY Interface, 9600 baud, None, 8/1 bits</b>\nThe interface integrated into the I/O module allows the connection of any device
Wago 750-650/000-013 fieldbus module RS-232 C Serial Interface, 4800 baud, Even, 7/2 bits
<b>RS-232 C Serial Interface; 4800 baud; Even; 7/2 bits</b>The interface integrated
Wago 750-645 fieldbus module <b>2-channel vibration velocity/bearing condition monitoring VIB I/O </b>\nThe VIB I/O modules are used for online monitoring of the mach
Wago 750-644 fieldbus module Bluetooth RF Transceiver
<b>Bluetooth® RF Transceiver </b>\nThe 750-644 I/O Module enables wireless exchange of process data with up to s
Wago 750-643 fieldbus module <b>MP-Bus Master </b>\nThe 750-643 I/O module acts as a master for the MP bus (Multi Point Bus from Belimo/Switzerland) and allows the bu
Wago 750-642 fieldbus module <b>Radio Receiver EnOcean </b>\nThe 750-642 I/O Module receives radio telegrams from maintenance-free, battery-less and wireless switches
Wago 750-641 fieldbus module <b>DALI/DSI master module </b>\nThe DALI standard (IEC 60929), a protocol across all manufacturers, ensures the interoperability of elect
Wago 750-640 fieldbus module <b>Real-time clock Module </b>\nThe 750-640 RTC Module provides the higher-level control system with the actual time.\n\nThe time is buff
Wago 750-638/025-000 fieldbus module 2 up/down counter, 500 Hz, Ext. Temperature
<b>2 up/down counter; 500 Hz; Ext. Temperature </b>\nThe I/O module has two counters that cou
Wago 750-638 fieldbus module 2 up/down counter, 16 bits, 500 Hz
<b>2 up/down counter; 16 bits; 500 Hz </b>\nThe I/O module has two counters that count 24VDC binary pu
Wago 750-637/000-002 fieldbus module Incremental encoder interface, 24 V DC; Single-ended, 32 bits
<b>Incremental encoder interface; 24 VDC; Single-ended; 32 bits </b>\nThis
Wago 750-637 fieldbus module Incremental encoder interface, RS-422, 32 bits
<b>Incremental encoder interface; RS-422; 32 bits </b>\nThis module is an interface for in
Wago 750-630/000-012 fieldbus module SSI transmitter interface, 13 bits, 125 kHz, Gray code
<b>SSI transmitter interface; 13 bits; 125 kHz; Gray code</b> \nThis module is an
Wago 750-630/000-009 fieldbus module SSI transmitter interface, 13 bits, 250 kHz, Binary code
<b>SSI transmitter interface; 13 bits; 250 kHz; Binary code </b>\nThis module is
Wago 750-630/000-008 fieldbus module SSI transmitter interface, 25 bits, 125 kHz
<b>SSI transmitter interface; 25 bits; 125 kHz; Gray code </b>\nThis module is an SSI interfa
Wago 750-630/000-001 Analog input module fieldbus module SSI transmitter interface, Fail-safe 2 channel analog input, 125 kHz, Binary code
<b>SSI transmitter interface; Fail-safe 2 channel analog inpu
Wago 750-628 fieldbus module <b>Bus Extension Coupler Module</b>\nThe coupler module for the internal data bus extension module 750-628 replaces the fieldbus coupler/
Wago 750-627 fieldbus module <b>Bus Extension End Module</b>\nThe end module for the internal data bus extension 750-627 is attached to the end of the I/O terminal bl
Wago 750-623 fieldbus module DC 24 V / 5 V - 15 V
<b>Power Supply; 24 V/5 … 15 VDC </b>\nThe I/O module generates 5V, 8V, 10V, 12V and 15V DC output voltages from the
Wago 750-622 fieldbus module <b>Binary Spacer Module </b>\nBinary spacer modules reserve bit addresses in the process image of a fieldbus node.\n\nThe operating mode
Wago 750-621 fieldbus module <b>Distance Module</b>\nThe separation module visually divides a fieldbus node into sections.\nSeparation module 750-621 has power jumper
Wago 750-616 fieldbus module <b>Distance Module </b>\nThe separation module visually divides a fieldbus node into sections.\nSeparation module 750-616 has no power ju
Wago 750-370 fieldbus module Fieldbus Coupler PROFINET IO, 2nd Generation
<b>Fieldbus Coupler PROFINET IO; 2nd Generation</b>\nThis fieldbus coupler connects to the W
Wago 750-352 fieldbus module Fieldbus Coupler ETHERNET, 3rd Generation
<b>Fieldbus Coupler ETHERNET; 3rd Generation</b>\nThe 750‐352 ETHERNET Fieldbus Coupler connect
Wago 750-348 fieldbus module Fieldbus Coupler CANopen, D-Sub, ECO
<b>Fieldbus Coupler CANopen; D-Sub; ECO </b>\nThe ECO fieldbus coupler is designed for applications
Wago 750-315 fieldbus module Fieldbus Coupler MODBUS, RS-485, 115.2 kBd, DC 24 V
<b>Fieldbus Coupler MODBUS; RS-485; 115,2 kBd </b>\nThis fieldbus coupler allows conn
Wago 750-409 Digital input module fieldbus module 4-channel digital input; 24 VDC; 0.2 ms; Low-side switching
This digital input module receives control signals from digital field devices (e.g., sens
Wago 750-404/000-004 Digital output module fieldbus module Up/Down Counter; Switching Output, 24 V
The counter acquires 24V binary pulses and transports the counter status to the installed bus system.\n\nThe
Wago 750-612 fieldbus module Power Supply; 0 … 230 V AC/DC
The supply module provides the I/O modules with the corresponding supply potential.\n\nThe maximum current at the suppl
Wago 750-650/000-015 Serial data exchange module fieldbus module RS-232 C Serial Interface; 4800 baud; Even; 8/1 bits; 5 bytes
The interface integrated in the I/O module allows the connection of any device which is
Wago 750-610 fieldbus module Power Supply; 24 VDC; fuse holder; Diagnostics
The supply module provides the I/O modules with the corresponding supply potential.\n\nThe maximum cur
Wago 750-404/000-001 Digital output module fieldbus module Up Counter; Release Input, 24 V
The counter acquires 24V binary pulses and transports the counter status to the installed bus system.\n\nCounting is
Wago 750-613 fieldbus module System Power Supply; 24 VDC
The internal system supply module increases the current supply for the internal system by 2A.\n\nIf the internal current
Wago 750-602/025-000 fieldbus module Power Supply; 24 VDC; Ext. Temperature
The supply module provides the I/O modules with the corresponding supply potential.\n\nThe maximum current at
Wago 750-602 fieldbus module Power Supply; 24 VDC
The supply module provides the I/O modules with the corresponding supply potential.\n\nThe maximum current at the supply module
Wago 750-404/000-005 fieldbus module 2 up counter; 16 bits
The I/O module is equipped with two 16-bit up counters.\n\nThe CLOCK 1 and CLOCK 2 inputs acquire 24V binary pulses and transmi
Wago 750-604 fieldbus module Potential Distribution; 8-way 0 V
The field side connection module provides 0 V potential for the outputs of the 8-channel output module 750-530.\n\n
Wago 750-614 fieldbus module Potential Distribution, 0 V - 230 V AC/DC
Field side connection module for multiple tapping of the supply voltage.\n\nThis eliminates the need for ad
Wago 750-404/000-002 Digital output module fieldbus module Peak Time Counter, DC 24 V
The counter acquires 24V binary pulses over a defined time period (gate time) and transports the counter status to the ins
Wago 750-635 fieldbus module Digital impulse interface, RS‐422
The digital impulse interface is designed for the connection of magnetostrictive distance measurement sensors with
Wago 750-404/000-003 Digital output module fieldbus module Frequency Counter, 24 V
The counter is used for frequency measurement here, with the pulse period of the 24V signal being measured at the CLOCK input
Wago 750-603 fieldbus module Potential Distribution; 8-way 24 V
Field side connection module for multiple tapping of the supply voltage.\n\nThis eliminates the need for additiona